Skip to content
Guide No CP-028Appliances

Vaillant F.75 Error: Pump & Pressure Sensor Fault Fix

Estimated time: ~8 min6 stepsLast verified:

Independent guide — no official affiliation with the platforms mentioned.

Short answer

Vaillant F.75 means the pump starts but the pressure sensor doesn't detect the expected pressure change — usually a blocked pressure sensor, air in the system or a faulty pump. First bring the water pressure to 1.2–1.8 bar, bleed the radiators and reset the boiler. If it persists after 2–3 attempts, the pressure sensor or pump needs service.

Official source

vaillant.com.tr

Vaillant Türkiye resmî sitesi

F.75 birkaç adımdan sonra çözülmezse yetkili servis randevusu buradan alınır.

01 — Step-by-step fix

Step-by-step fix

  1. Check and refill pressure to 1.2–1.8 bar

    If the display shows below 0.8 bar, F.75 triggers. Open the filling loop under the boiler slowly and close it when the display reaches 1.2–1.8 bar. Make sure the filling tap is fully closed afterwards.

  2. Bleed the radiators

    Trapped air confuses the pump's pressure detection. Open each radiator's bleed valve slowly; when hissing stops and water appears, close it. Start with the radiators on the highest floor.

    Bleeding drops the pressure by 0.3–0.5 bar; top it back to 1.2–1.8 bar once done.

  3. Reset the boiler

    Press the reset/power button or switch off the boiler's breaker for 30 seconds. When it restarts, watch whether F.75 returns.

  4. Open the heating valves fully

    Half-closed flow/return valves cause pressure swings. Make sure the service valves below the boiler are fully open and any filter/dirt trap isn't clogged.

  5. Check for frozen condensate pipes

    In winter, frozen external pipes stop circulation and can raise F.75. Thaw them first, then reset. Don't force the boiler to run against a frozen system.

    Running the boiler against a frozen system can damage the pump and heat exchanger. Keep the boiler in standby until thawed.

  6. If it persists: pressure sensor / pump service

    After the steps above, a persistent F.75 points to a blocked or failed pressure sensor or a pump problem. These are authorized-service jobs — don't open the boiler yourself while under warranty.

Tips

  • An annual system filter cleaning prevents the most common cause: a blocked sensor.
  • Keeping the boiler in summer mode instead of full off prevents pump seizing.
  • Pressure keeps dropping? That's a separate fault — see our 'boiler pressure keeps dropping' guide.

02 — Frequently asked questions

Frequently asked questions

Can F.75 clear by itself?

If caused by air or a temporary pressure dip, it clears after refill, bleeding and reset. Sensor blockage or pump failure won't clear without service.

How much does F.75 repair cost?

Typically a pressure sensor cleaning/replacement or pump repair. Under warranty parts and labour are free; otherwise get a quote from authorized service.

Difference between F.75 and F.28?

F.28 is an ignition/flame fault (gas arrives, no flame detected); F.75 is the pressure change not being detected when the pump starts. Both can relate to pressure and air, but the fixes differ.

Links in this guide point to official platform pages. Steps may change with platform updates; check the page date.

03 — Related guides

Boiler & Appliances