Boiler Pressure Too Low: How to Refill to 1.5 Bar
Independent guide — no official affiliation with the platforms mentioned.
Kurze Antwort
When boiler pressure drops below 1.0 bar, slowly open the filling loop underneath until the gauge reads 1.5 bar, then close it. It takes 2–3 minutes. Frequent drops indicate a leak or faulty expansion vessel — call a technician.
01 — Schritt-für-Schritt-Lösung
Schritt-für-Schritt-Lösung
STEP 01
Let the boiler cool down
Refilling a hot system gives false readings due to expansion. Switch off and wait 15–20 minutes.
STEP 02
Find the filling loop
It's a small tap or flexible connector under the boiler, labelled 'filling loop' in the manual.
STEP 03
Raise pressure to 1.5 bar
Open the valve slowly and watch the gauge. Close it fully at 1.5 bar.
Above 2.5 bar the safety valve discharges water. Never fill beyond 2 bar.
STEP 04
Bleed radiators if needed
Open radiator bleed valves until water appears, then re-check the pressure.
STEP 05
Log frequent drops
If pressure drops more than once a week, suspect a leak or expansion-vessel membrane — call service.
Tipps
- Forgetting the filling loop open is the most common mistake — re-check after an hour.
- Photograph the gauge to track changes over time.
02 — Häufig gestellte Fragen
Häufig gestellte Fragen
What should boiler pressure be?
1.0–1.5 bar when cold is ideal. Rising to 2.0 bar during heating is normal; 3 bar is the safety limit.
Pressure keeps dropping — what should I do?
Check visible leaks first (valves, filling loop). If none, the expansion vessel membrane may be faulty — needs a technician.
How do I lower excessive pressure?
Bleed a radiator slightly to release water until it returns to 1.5 bar. Don't use the boiler's drain valve.