Boiler Pressure Keeps Dropping: Causes and Home Fixes
Short answer
If you refill every 1–2 weeks, something is losing water: the usual suspects are weeping radiator bleed valves, a not-fully-closed filling loop, silent discharge through the safety valve or a failed expansion vessel. Check the loop and valve first; if pressure rises while heating then falls, the expansion vessel must be tested.
01 — Step by Step
Step-by-step fix
-
Make sure the filling loop is fully closed
A half-closed or worn loop lets water through silently, pushing pressure up and opening the safety valve. Close it fully and wrap it with a dry tissue for 1–2 days: a wet tissue means the loop must be replaced.
-
Check the safety valve and discharge pipe
Drips or moisture marks on the copper discharge pipe under the boiler mean the system vents through the valve — often a sign of expansion vessel failure or overpressure.
-
Inspect bleed valves and joints
Look for dark water marks or damp under bleed screws, radiator unions and the pipework under the boiler. Small leaks evaporate while silently dropping pressure.
-
Test the expansion vessel
Note the cold pressure, then run heating: a rise above 1 bar that shoots to 3 bar and opens the valve means the vessel has lost its air charge. The Schrader valve under its plastic cap can be checked/recharged (0.8–1 bar); a failed membrane needs service.
-
No visible leak? Book a leak test
Underfloor/wall pipework hides leaks. Thermal camera, pressure and tracer tests locate the point and avoid needless wall demolition.